List your agent

ScienceShot science reference

MCP server · hosted · v1.2.0 · com.scienceshot/science
Online · tested 7h agoNEW · 7h agoSeen in the registry 6h ago

Sourced, citable answers in radiation and particle physics, photonics, electronics and quantum.

What it does

ScienceShot science reference is an MCP server, a connector that lets an AI assistant use it as a tool. It is hosted: an assistant connects to it over the internet, nothing to install.

No capability identified yet from its description.

Facts come from the Official MCP Registry, as declared by the publisher. Capabilities are matched automatically (low confidence). None of this is a test of the tool.

At a glance

Hosted (remote)YES
Local installNO
Version1.2.0
PriceNot in the registry
First seen07 Nov 2026
Last checked6h ago

How to connect

As declared in the Official MCP Registry · hosted endpoint tested by Electra Index 7h ago (live check)

Hosted endpoint

  • https://scienceshot.com/mcp streamable-http

In Claude Code: claude mcp add --transport http scienceshot-science-reference https://scienceshot.com/mcp

MCP settings (Claude Desktop, Cursor and other MCP clients)

{
  "mcpServers": {
    "scienceshot-science-reference": {
      "url": "https://scienceshot.com/mcp"
    }
  }
}

Live check

Electra Index connected to the hosted endpoint 7h ago

ONLINE ScienceShot science reference answered an MCP connection on 07 Nov 2026 and introduced itself as scienceshot 1.0.0 (MCP protocol 2025-06-18).

26 tools offered to AI assistants

  • search_scienceshot · Search ScienceShot's science reference pages and articles on radiation and particle physics, photonics, electronics and quantum physics. Returns up to 5 pages with title, date, link and summary.
  • photon_energy · Convert vacuum wavelength, frequency, spectroscopic wavenumber and photon energy with CODATA 2018 constants. Returns photon rate for optical power, photons per joule, momentum and all matching overlapping ISO 21348 spectral categories.
  • blackbody_spectrum · Calculate both Wien peaks, Planck peak spectral radiances and Stefan-Boltzmann radiant exitance for an ideal blackbody from 1 K to 100000 K. Numerically integrates the fraction of total power in a wavelength band, default 380-760 nm, using
  • semiconductor_carriers · Calculate Varshni bandgap, intrinsic and doped equilibrium carriers, Fermi level above the valence edge and conductivity for Si, Ge or GaAs. Assumes fully ionized dopants and non-degenerate statistics; conductivity uses fixed 300 K low-fiel
  • noise_calculator · Calculate Johnson-Nyquist thermal noise voltage, current and available power kTB, Schottky shot noise, noise figure and noise temperature (290 K reference), input noise floor and SNR in dB, and the ideal ADC quantization SNR (6.02 N + 1.76
  • radioactive_decay · Calculate parent and daughter activities using NuDat 3 half-lives and branching. Supply an isotope ID, initial activity and elapsed time with units.
  • xray_spectrum · Calculate a tungsten tube spectrum, mean energy (fluence-weighted), aluminium and copper half-value layers, air kerma and the fraction of kerma removed by added filters. Uses SpekPy 2.5.4 with 12 degree anode and 2.5 mm Al inherent filtrati
  • cosmic_dose · Calculate the cosmic-ray ambient dose equivalent rate H*(10) and effective dose rate E (ICRP 116), in uSv/h, inside an aircraft cabin (0-20 km) or on the ground (0-6 km), for a latitude, longitude and solar activity, and the effective dose
  • gamma_dose_rate · Compute a point-source air-kerma rate constant from listed NNDC photon lines and NIST air energy-absorption coefficients, with resolved LNHB photon supplements. Apply activity and inverse-square distance with optional line-by-line shielding
  • synchrotron_loss · Calculate dipole synchrotron energy loss per turn, radiated power per beam and critical photon energy in an isomagnetic ring. Give total beam energy including rest energy, beam current and exactly one bending radius or dipole field; an opti
  • bragg_peak · Calculate proton CSDA range, stopping power, Bragg peak, distal R80 and relative dose per fluence in water or ICRU soft tissue. Uses Bethe range and Bortfeld (1997) with Gaussian straggling and initial energy spread; tissue is water-equival
  • diffraction_grating · Solves the signed reflection grating equation and ideal Rayleigh resolution from Hecht, Optics, 5th edition and the MKS Newport handbook. Returns allowed order bounds, angular dispersion, illuminated groove count, linewidth, Littrow angle a
Show 14 more
  • photodiode_responsivity · Converts external quantum efficiency and responsivity using CODATA 2018 h, c and e, and computes photocurrent and unity-gain shot noise following Hamamatsu. Returns dark and illuminated shot-noise NEP, sourced Si/Ge/In0.53Ga0.47As bandgap t
  • gaussian_beam · Gaussian propagation and thin-lens focusing from Siegman, Lasers (1986), with ISO 11146 beam propagation ratio. Returns Rayleigh range, radius, curvature, Gaussian-model Gouy phase, half-angle divergence, focused waist, depth of focus and p
  • fibre_link_budget · Power margin and fixed-component power reach from ITU-T G.652.D cable attenuation maxima. Returns chromatic broadening and a dispersion-limited estimate using explicit spectral width and allowed bit-period fraction; excludes chirp, PMD, non
  • microstrip_impedance · Calculate microstrip impedance and effective permittivity with Hammerstad-Jensen (1980) thickness correction. Returns Wheeler (1977) zero-thickness synthesis and a separate thickness-corrected H-J target width; dispersion and losses are ign
  • qubit_coherence · Calculate single-qubit average fidelity under Markovian amplitude/phase damping using Nielsen (2002). Accept T1, T2 or Tphi and gate time; checks T2 <= 2T1 and returns pure dephasing, error per gate and an independent-error depth proxy, not
  • hydrogen_spectrum · Calculate reduced-mass Rydberg vacuum and standard-air wavelengths, level energies and ionization energies for H, D or a one-electron ion. Supply integer lower and upper levels; custom ions need Z and a bare nuclear mass in kg. Air uses Edl
  • quantum_tunnelling · Calculate the exact transmission coefficient of a one-dimensional rectangular potential barrier for an electron, proton or alpha particle, below or above the barrier height. Give particle energy and barrier height in eV and barrier width in
  • convert_radiation_units · Convert a radiation value between units of the same quantity. Gy and Sv are never converted into each other: that needs a radiation weighting factor.
  • photon_attenuation · Narrow-beam photon attenuation from NIST XCOM. Give thickness in mm and energy in keV.
  • energy_loss · Bethe and Landau thin-absorber estimates and a CSDA range for a heavy charged particle. The range is truncated at beta*gamma 0.05; give momentum or kinetic energy and thickness.
  • material_properties · Density, Z/A, mean excitation energy, radiation length, nuclear interaction and collision lengths, electron critical energy, Moliere radius and available melting and boiling points for 17 materials. Lengths are returned in g/cm2 and cm usin
  • detector_signal · Most probable and mean electron-hole pairs, collected charge, energy deposit and Landau FWHM. Assumes full collection without gain; Si at 300 K, Ge at 77 K. Defaults: muon, 3000 MeV/c, silicon, 300 micrometres.
  • landau_distribution · Heavy-particle energy-loss distribution with MPV, Landau FWHM, finite-transfer Bethe mean, xi, kappa, regime, peak constants and 161 Landau density points. Gaussian regimes include sigma_mev; the returned Landau curve is then inapplicable.
  • device_ledger_query · Query the ScienceShot QEP device ledger: published measurements of qubit coherence (T1, T2), single- and two-qubit gate fidelity, readout fidelity and gate time on superconducting, trapped-ion, neutral-atom, semiconductor-spin, defect-spin

What "online" means: the server answered an MCP connection at the time of the check. It is not a guarantee of security, quality or continuous uptime. How we test: we open an MCP session and ask for the tool list, as an AI assistant would. We never run a tool and never send a key. Checked every few days. Method

Is this your server? Monitoring Pro: a check every 30 minutes and an email within the hour when it stops answering. Launch offer: $39.99 once, for life.

Facts & evidence

Each fact shows where it was seen and when.
FactValueEvidenceSourceLast confirmed
Hosted endpointhttps://scienceshot.com/mcpDECLAREDSRC-001 Official MCP Registry6h ago
Local install (package)noDECLAREDSRC-001 Official MCP Registry6h ago
Remote access (hosted)yesDECLAREDSRC-001 Official MCP Registry6h ago
Websitehttps://scienceshot.com/ai-connectorDECLAREDSRC-001 Official MCP Registry6h ago
Registry statusactiveDECLAREDSRC-001 Official MCP Registry6h ago
Version1.2.0DECLAREDSRC-001 Official MCP Registry6h ago
MCP serveryesDECLAREDSRC-001 Official MCP Registry6h ago

Change history

  • NEW07 Nov 2026
    first seen in the index

Is this page accurate?

Flag it and our robot re-checks the official source. Reports never change a score.

Do you run ScienceShot science reference? Know when it stops answering

For publishers · optional

Its hosted endpoint can be monitored. Monitoring Pro connects every 30 minutes like an AI assistant, emails you within the hour when it stops answering, keeps a 90-day availability history and adds your answer rate to your badge.

Monitor ScienceShot science referenceLaunch offer $39.99 once, for life instead of $9.99/month · All plans

Monitoring never changes a score or a rank.

Are you the publisher of ScienceShot science reference?

Free · show your listing

An independent listing builds trust with your buyers. Announce it, and add the badge to your website or README.

Announce it on LinkedInListed on Electra Index
<a href="https://electraindex.com/mcp/scienceshot-science-reference?utm_source=badge&utm_medium=share&utm_campaign=listing"><img src="https://electraindex.com/api/badge/scienceshot-science-reference" alt="Listed on Electra Index"></a>

Questions about ScienceShot science reference

How do I connect ScienceShot science reference?

Use the hosted endpoint https://scienceshot.com/mcp in your assistant's MCP settings. The exact settings are in "How to connect" above, as declared in the Official MCP Registry.

What tools does ScienceShot science reference offer?

When Electra Index connected on 07 Nov 2026, it listed 26 tools: search_scienceshot, photon_energy, blackbody_spectrum, semiconductor_carriers, noise_calculator, radioactive_decay, xray_spectrum, cosmic_dose and more. The full list is in "Live check" above.

Is ScienceShot science reference online?

Yes. Its hosted endpoint answered an MCP connection from Electra Index 7h ago.