List your agent

Synergieloc — French real estate & building CAD/BIM

MCP server● Hosted · onlinev1.2.1

French real-estate law and building CAD/BIM (DXF, IFC). /mcp/v2: lightweight catalogue

Reviews

No review yet. Used Synergieloc — French real estate & building CAD/BIM? Be the first to help others choose.

What it does

Synergieloc — French real estate & building CAD/BIM is an MCP server, a connector that lets an AI assistant use it as a tool. It is hosted: an assistant connects to it over the internet, nothing to install.

No capability identified yet from its description.

Facts come from the Official MCP Registry, as declared by the publisher. Capabilities are matched automatically (low confidence). None of this is a test of the tool.

At a glance

Hosted (remote)YES
Local installNO
Version1.2.1
PriceNot in the registry
First seen26 Sept 2026
Last checked20h ago

How to connect

As declared in the Official MCP Registry · hosted endpoint tested by Electra Index 5h ago (live check)

Hosted endpoints

  • https://synergieloc.fr/mcp streamable-http
  • https://synergieloc.fr/mcp/v2 streamable-http

In Claude Code: claude mcp add --transport http immobilier https://synergieloc.fr/mcp

MCP settings (Claude Desktop, Cursor and other MCP clients)

{
  "mcpServers": {
    "immobilier": {
      "url": "https://synergieloc.fr/mcp"
    }
  }
}

Live check

Electra Index connected to the hosted endpoint 5h ago

ONLINE Synergieloc — French real estate & building CAD/BIM answered an MCP connection on 17 Nov 2026 and introduced itself as synergieloc-immobilier 1.0.0 (MCP protocol 2025-06-18).

560 tools offered to AI assistants

  • cao_bim_conformite · Appelez quand vous devez etablir le bilan BIM consolide d'une scene CAO (LOD/LOI, completude, conformite, nommage, disciplines, quantitatif) pour une phase donnee. Renvoie un score 0-100, le verdict et les ecarts, sans modifier la scene. Ph
  • cao_bim_aller_retour · Appelez quand vous devez verifier l'aller-retour IFC complet d'une scene CAO : exporte en IFC4 (ifcopenshell), reimporte et compare semantiquement. Garantit qu'aucun element n'est perdu ni deplace de niveau ; signale les ajouts (toiture/pla
  • cao_bim_disciplines · Appelez quand vous devez attribuer chaque element d'une scene CAO a sa discipline (architecture, structure, MEP, electricite, plomberie, CVC, paysage, voirie), donne l'effectif par discipline et la matrice de coordination (paires de metiers
  • cao_bim_modele · Appelez quand vous devez construire le modele semantique BIM d'une scene CAO (identifiants stables, niveau, dimensions, materiau, libelle) et verifie l'aller-retour JSON sans perte. Lecture seule, sans modifier la scene.
  • cao_bim_familles · Appelez quand vous devez lister les familles parametriques standard (action=standard, defaut), lister les familles data-driven avec catalogue de types fabricants (action=parametrique), evaluer une famille definie en donnees avec formules te
  • cao_bim_doe · Appelez quand vous devez produire la documentation fine de fin de chantier (DOE) : fiches de local (action=fiches, defaut), nomenclature des finitions avec totaux par materiau (action=finitions) ou sommaire DOE present/manquant (action=doe)
  • cao_bim_federation · Appelez quand vous devez federer plusieurs modeles ou batiments d'un grand projet (worksharing) : relie chaque modele a sa discipline, detecte les elements dupliques et les collisions de noms, synchronise les reservations dans un registre c
  • cao_bim_fabricants · Appelez quand vous devez consulter ou etendre le catalogue de familles fabricants (menuiseries, sanitaires, chauffage, ventilation, electricite, structure, cloison_isolation) : stats (action=stats, defaut), recherche (action=rechercher), ev
  • cao_bim_dtu · Appelez quand vous devez verifier la conformite d'une scene aux normes d'execution francaises (DTU) : epaisseurs des murs cloison/porteur (DTU 20.1), alleges et appuis des fenetres (DTU 36.5), garde-corps (NF P01-012), pentes de couverture
  • cao_bim_sismique · Appelez quand vous devez predimensionner un batiment au seisme (Eurocode 8, indicatif) : zonage sismique FR (1-5), spectre de reponse elastique, periode T1, effort tranchant a la base par la methode des forces laterales et sa repartition pa
  • cao_bim_options · Appelez quand vous devez comparer des options de conception (variantes A/B) d'un projet : chaque variante est une scene nommee, et la comparaison est CALCULEE (quantitatif, cout 5D, delai 4D pondere par la surface). action=comparer (defaut)
  • cao_bim_terrain · Appelez quand vous devez analyser un terrain et son terrassement depuis des points topographiques : pente moyenne et maximale (plan ajuste), volumes de deblai/remblai pour une plateforme, altitude qui equilibre deblai=remblai, et conseils (
Show 88 more
  • cao_bim_cctp · Appelez quand vous devez rediger le CCTP (cahier des clauses techniques particulieres) d'une scene : les 11 lots du marche (gros oeuvre, charpente, menuiseries, platerie, electricite, plomberie, chauffage, sols, peinture...) avec leurs clau
  • cao_bim_reception · Appelez quand vous devez produire les reserves et le PV de reception d'une scene : les ecarts DTU deviennent des reserves numerotees rattachees a leur lot, les reserves se levent avec preuve (levee_ids + acteur + date), et la reception DECI
  • cao_bim_portfolio · Appelez quand vous devez consolider PLUSIEURS projets BIM en un portefeuille (vue bureau d'etudes) : statistiques (score moyen, cout total, prets/bloques, a signer), lignes par projet et classement (les bloques en tete). Entree : scenes=[{n
  • cao_bim_maintenance · Appelez quand vous devez produire le carnet d'entretien (exploitation) d'une scene : chaque equipement (chaudiere, PAC, VMC, chauffe-eau, climatiseur, ascenseur...) recoit sa periodicite d'entretien et ses OBLIGATIONS legales (chaudiere ann
  • cao_bim_lod · Appelez quand vous devez evaluer le niveau de developpement (LOD) et d'information (LOI) de chaque element d'une scene CAO, et le valide contre la phase du projet (esquisse, aps, apd, dce, execution). Rend les exigences par phase, l'evaluat
  • cao_bim_cde · Appelez quand vous devez decrire l'environnement de donnees commun (CDE, ISO 19650) : machine d'etats brouillon -> soumis -> approuve/rejete -> remplace, transitions gardees, et deroule un cycle de vie d'exemple avec piste d'audit et verifi
  • cao_bim_livraison · Appelez quand vous devez decider de la livraison BIM (BIM Execution Plan) : verifie que la maquette atteint le LOD/LOI, la completude, le nommage et la conformite exiges par la phase (esquisse/aps/apd/dce/execution). Renvoie {autorise, scor
  • cao_bim_bcf · Appelez quand vous devez generer des issues BCF (BIM Collaboration Format 2.1) depuis les ecarts de l'aller-retour IFC d'une scene (action par defaut : scene + markup XML pret pour Solibri/BIMcollab), depuis les RESERVES de reception (actio
  • cao_bim_reglementations · Appelez quand vous devez controler la conformite d'une scene CAO selon la reglementation du TERRAIN du projet (France, Etats-Unis IBC/ADA, Suisse SIA 500, Royaume-Uni Approved Documents). Verifie escaliers, portes, garde-corps et rampes ; r
  • cao_bim_projet · Appelez quand vous devez obtenir la vue projet complete selon le TERRAIN : reglementation applicable (FR/USA/CH/GB), verdict de conformite, bilan BIM, decision de porte et manifeste des livrables — ou, avec action=dossier, LE DOSSIER BIM CO
  • cao_bim_4d5d · Appelez quand vous devez estimer le cout (5D) et le planning de construction (4D) d'une scene CAO : quantitatif x taux unitaires, taches filtrees par phase BEP (action=bilan, defaut), la COURBE EN S du cout cumule dans le temps (action=cour
  • cao_bim_mep · Appelez quand vous devez verifier ou dimensionner un systeme MEP : connectivite et dimensionnement d'un reseau (action=reseau, defaut), debits cumules calcules d'un reseau hydraulique (action=debits, reseau + demandes), pertes de charge du
  • cao_bim_structure · Appelez quand vous devez obtenir un ordre de grandeur de calcul structure (EC2 simplifie) : poutre, dalle, poteau, effort tranchant, flexion composee, flambement, moment de dalle bidirectionnelle (moment_dalle), poinconnement, dalle complet
  • cao_bim_energie · Appelez quand vous devez estimer la valeur U (W/m2K) d'une paroi composee, les deperditions, le bilan thermique, le Cep, le Bbio — ou l'ETIQUETTE DPE 2021 (A-G) d'un logement : donnez cep_kwh_m2 + ges_kgco2_m2 et le verdict (passoire ou non
  • cao_bim_acv · Appelez quand vous devez estimer le CARBONE de la construction (ACV) d'une scene : quantites lues dans la maquette (murs, dalles/planchers, couvertures, menuiseries) x facteurs d'emission FDES/INIES, total et ratio kgCO2e/m2 face aux seuils
  • cao_bim_incendie · Appelez quand vous devez verifier la SECURITE INCENDIE d'une scene (habitation ou ERP) : distances d'evacuation (10 m habitation / 40 m ERP, code du travail R. 4216-2), nombre d'issues selon l'effectif (CO 38), unites de passage (CO 36), po
  • cao_bim_accessibilite · Appelez quand vous devez auditer l'ACCESSIBILITE PMR d'une scene (ERP, bureaux ou habitation ADAP) : portes d'entree >= 0,90 m (0,83 habitation), cheminements >= 1,20 m avec pentes <= 5 % et ressauts <= 2 cm, portes interieures >= 0,80 m, e
  • cao_bim_acoustique · Appelez quand vous devez verifier l'ACOUSTIQUE d'une scene contre la NRA (arrete 30/06/1999) : bruits aeriens entre logements (DnT,A >= 53 dB), bruits de choc (L'nT,w <= 58 dB), bruits d'equipements (LnAT <= 30/35 dB(A)) et facades (DnT,A,t
  • cao_bim_economie_circulaire · Appelez quand vous devez produire le diagnostic PEMD (Produits-Equipements-Materiaux-Dechets, loi AGEC / decret PMCB) d'une scene avant demolition ou rehabilitation : masses par materiau, filieres (reemploi / recyclage / valorisation / enfo
  • cao_bim_eclairage · Appelez quand vous devez verifier l'ECLAIRAGE NATUREL (FLJ) d'une scene : surface vitree >= 1/6 de la surface de chaque piece (reglement sanitaire / RE2020) et FLJ estime >= 2 % (EN 17037 / code du travail R. 4223). Le FLJ est calcule depui
  • cao_bim_descente_charges · Appelez quand vous devez descendre les charges d'une scene jusqu'au sol et verifier les fondations : poids propres (dalles 25 kN/m3, murs par materiau), charges d'exploitation par usage (EC1-1-1 : habitation 1,5 / bureau 2,5 / commerce 3,5
  • cao_bim_vent · Appelez quand vous devez estimer les CHARGES DE VENT sur un batiment (Eurocode 1-1-4, indicatif) : pression dynamique de pointe qp(z) selon la region (vitesse de base 22-28 m/s) et la categorie de terrain (0-IV), pression sur la facade (cpe
  • cao_bim_grue · Appelez quand vous devez choisir la GRUE DE CHANTIER et verifier ses levages depuis la maquette : portee couvrant l'emprise + 2 m, chaque levage (masse_kg, position x/y) dans la portee ET dans la courbe de charge (interpolation max -> bout
  • cao_bim_securite_chantier · Appelez quand vous devez verifier la SECURITE DU CHANTIER (PPSPS, indicatif) : protections collectives contre les chutes (garde-corps provisoires/filets sur dalles et toitures en travaux, tremies obturees ou balisees), echafaudages (planche
  • cao_bim_eaux_pluviales · Appelez quand vous devez dimensionner la GESTION DES EAUX PLUVIALES d'une parcelle : surface active (toitures, voiries, espaces verts x coefficients de ruissellement), volume de retention requis par la methode des pluies simplifiee (pluie d
  • cao_bim_biotope · Appelez quand vous devez verifier la BIODIVERSITE d'une parcelle (coefficient de biotope du PLU) : CBS = somme(surfaces eco-amenageables x coefficient) / parcelle, avec pleine terre 1,0 / espaces verts sur dalle 0,7 / toiture vegetalisee 0,
  • cao_bim_confort_ete · Appelez quand vous devez verifier le CONFORT D'ETE (surchauffe, RE2020) d'une scene : protections solaires sur les baies sud/ouest >= 1 m2 (bso/casquette/volet declares), inertie (dalle beton >= 12 cm), ventilation nocturne (ouvrants >= 4 %
  • cao_bim_geotechnique · Appelez quand vous devez choisir le SYSTEME DE FONDATION d'un batiment : la descente de charges (N ELU, murs porteurs) est confrontee au sol (capacite admissible, argile, remblai) et le systeme est recommande — semelles filantes, semelles e
  • cao_bim_etancheite · Appelez quand vous devez verifier l'ETANCHEITE A L'AIR (RE2020) d'un batiment : Q4Pa-surf <= 0,6 m3/(h.m2) maison / 1,0 collectif, points singuliers traites (menuiseries, traversees, trappes, gaines, conduits — membrane/mastic/joint), membr
  • cao_bim_ratios · Appelez quand vous voulez le TABLEAU DE BORD DE CONCEPTION d'une scene : SHAB, emprise et CES (emprise/parcelle <= 0,40), hauteur, surface deperditive et compacite (<= 1,2), ratio de vitrage (entre 1/6 et 30 %), cout/m2 (5D mercuriale BT, o
  • cao_bim_worksharing · Appelez quand PLUSIEURS acteurs doivent travailler sur la MEME maquette (worksharing) : creer une session (jeton + version), joindre, verrouiller/deverrouiller des elements, modifier avec detection des conflits (une modification basee sur u
  • cao_bim_placer · Appelez quand vous devez POSER un type du catalogue fabricants DANS la maquette (auteur) : placer(scene, famille, type, x/y/z) ajoute l'element dans le bon conteneur (ouvertures, murs, boites, poteaux, poutres, escaliers, equipements), vali
  • cao_bim_exe · Appelez quand vous devez produire le DOSSIER EXE MULTI-LOTS d'une scene : decoupage en 9 lots d'execution (gros oeuvre, charpente/couverture, menuiseries, cloisons, electricite, plomberie, CVC, sols, peinture) avec elements, quantites (ml/m
  • cao_bim_mep_dimensionnement · Appelez quand vous devez DIMENSIONNER LES DIAMETRES d'un reseau MEP : chaque troncon d'eau recoit le DN standard (12->110) par la methode des vitesses (0,4-1,5 m/s confort, 2,5 m/s limite) sur son debit cumule aval, avec la perte de charge
  • cao_bim_bordereau_armatures · Appelez quand vous devez produire le BORDEREAU D'ARMATURES (livrable ferrailleur) d'une scene : les barres declarees (element + barres [{diametre_mm, forme: droit|u|cadre|chapeau, quantite, dims}]) recoivent leur DEVELOPPE (NF A 35-027 : cr
  • cao_bim_planning_cpm · Appelez quand vous devez ordonnancer le chantier par la METHODE DU CHEMIN CRITIQUE (4D avance) : debut/fin au plus tot et au plus tard (ES/EF/LS/LF), marges, chemin critique (taches a marge nulle), detection des cycles de dependances, date
  • cao_bim_dossier_complet · Appelez quand vous voulez LE DOSSIER DCE COMPLET en un appel : le dossier historique (reglementation, bilan, gate, DTU, sismique, cout, planning, courbe en S, CCTP, terrain, note) PLUS toutes les pieces ajoutees — ACV carbone, securite ince
  • cao_bim_assurances · Appelez quand vous devez verifier les ASSURANCES OBLIGATOIRES de la construction : dommages-ouvrage souscrite AVANT l'ouverture du chantier (code des assurances L. 242-1), garantie decennale et RC pro de CHAQUE entreprise par lot (L. 241-1,
  • cao_bim_cvc · Appelez quand vous devez dimensionner le GENERATEUR CVC : puissance de chauffage requise (deperditions statiques U.S.dT + marge de relance 1,2), choix du plus petit appareil du catalogue (PAC air/eau 5-16 kW COP 3,2, chaudiere gaz condensat
  • cao_bim_eclairage_artificiel · Appelez quand vous devez verifier l'ECLAIRAGE ARTIFICIEL d'une scene : chaque piece contre le niveau requis par son usage (code du travail R. 4223-4 / EN 12464 — bureaux 300 lux, circulations 40, stockage 100...), eclairement moyen par la m
  • cao_bim_volumes_eau · Appelez quand vous devez verifier la SECURITE ELECTRIQUE DES SALLES D'EAU (NF C 15-100) : chaque appareil declare est classe dans son volume (0 baignoire/douche IPX7, 1 jusqu'a 2,25 m IPX4, 2 autour 0,60 m IPX2, hors), les prises sont inter
  • cao_bim_gaz · Appelez quand vous devez verifier la SECURITE GAZ d'une installation (arrete 2/08/1977, DTU 61.1) : ventilation du local chaudiere (amenee d'air basse >= 50 cm2 + evacuation haute >= 100 cm2), debouche du conduit >= 40 cm au-dessus du faita
  • cao_bim_ascenseur · Appelez quand vous devez verifier un ASCENSEUR (EN 81, arrete 20/04/2017) : gaine >= dimensions de la capacite (630 kg : 1,50 x 1,50 m ; 1000 kg : 1,90 x 1,90), fosse >= 1,10 m (1,20 pour 800-1000 kg), machinerie ventilee/eclairee, securite
  • cao_bim_qai · Appelez quand vous devez verifier la QUALITE DE L'AIR et les debits de ventilation d'un logement : debits d'extraction par local selon la taille (arrete 24/03/1982 — cuisine 45->135 m3/h, SDB 15->60, WC 15->30), equilibre soufflage/reprise
  • cao_bim_charpente · Appelez quand vous devez dimensionner la CHARPENTE BOIS (EC5/DTU 31.1) : chevrons et pannes sur appuis simples — charge lineaire (couverture 0,8 kN/m2 + neige 0,45) x entraxe, moment de flexion, contrainte s = M/W face au C24 (16,6 MPa), fl
  • cao_bim_mep_aeraulique · Appelez quand vous devez dimensionner le RESEAU DE GAINES COMPLET : debits des bouches cumules de l'aval vers la source, diametre normalise de chaque troncon par la friction constante (1 Pa/m), perte de chaque BRANCHE source->bouche, branch
  • cao_bim_4d_cpm · Appelez quand vous voulez la COURBE EN S DATEES par le chemin critique (4D avance) : chaque tache du CPM recoit ses dates reelles (ES/EF), le cout 5D est reparti par poids de tache (terrassement 5 %, structure 30 %, enveloppe 25 %, second o
  • cao_bim_vrd · Appelez quand vous devez verifier les VRD (voiries et reseaux divers) d'une scene : pentes de voirie entre 0,5 et 15 %, regards au moins tous les 30 m et a chaque changement de direction, branchements EU (pente 1-2,5 %, diametre >= 100 mm)
  • cao_bim_evacuation · Appelez quand vous devez verifier l'EVACUATION d'un batiment : issues signalees (pictogrammes eclaires), BAES (>= 1 par issue + 1 par niveau), plan d'evacuation affiche a chaque niveau, issues degagees, et PARCOURS horizontaux (distance pie
  • cao_bim_certification · Appelez quand vous voulez le SCORECARD DE CERTIFICATION ENVIRONNEMENTALE (HQE/BREEAM-like) d'une scene : 4 familles (energie-carbone : etancheite, confort d'ete, carbone ACV ; environnement-eau : biotope, eaux pluviales, economie circulaire
  • cao_bim_eau · Appelez quand vous devez verifier la CONSOMMATION D'EAU POTABLE d'un logement : estimation annuelle (120 L/j/occupant, -20 % avec appareils economes — chasse 3/6 L, mousseurs), recuperation d'eau de pluie (arrosage 60 L/m2/an + sanitaires,
  • cao_bim_toiture_terrasse · Appelez quand vous devez verifier une TOITURE-TERRASSE (NF DTU 43) : pente de la partie courante entre 1 et 5 %, releves d'etancheite >= 150 mm au-dessus du niveau fini, evacuations EP (>= 2, diametre >= 100 mm, une par tranche de 150 m2),
  • cao_bim_vitrages · Appelez quand vous devez verifier les VITRAGES DE SECURITE (NF DTU 39 / NF P78) : vitrages en allege (bas < 1,00 m, chute > 1 m -> feuillete 44.2), portes vitrees pleine hauteur (feuillete 44.2 ou trempe REPERE), garde-corps vitres (feuille
  • cao_bim_condensation · Appelez quand vous devez verifier le RISQUE DE CONDENSATION d'une paroi (methode de Glaser, NF EN ISO 13788) : profil de temperature et de pression de vapeur a travers les couches declarees (materiau, epaisseur_mm, lambda/mu par defaut), co
  • cao_bim_bardage · Appelez quand vous devez verifier un BARDAGE RAPPORTE (regles professionnelles) : lame d'air ventilee >= 20 mm, pare-pluie HPV declare, ossature (bois/alu) et fixations (espacement <= 600 mm), jeu en pied >= 150 mm (rejingot) et joints de d
  • cao_bim_lod_instances · Appelez quand vous devez verifier le LOD/LOI D'EXECUTION des instances posees : chaque instance atteint LOD 350 (dimensions nominales), 400 (+ position) ou 500 (fabricant + reference, tel que construit), et le niveau atteint est confronte a
  • cao_bim_bordereau_lots · Appelez quand vous voulez les BORDEREAUX QUANTITATIFS EXE par lot (unites d'oeuvre d'agence) : beton m3 (murs banches, dalles), COFFRAGE m2 (sous-faces + rives de dalles, 2 faces des murs), acier kg (bordereau d'armatures), cloisons m2, cou
  • cao_bim_foudre · Appelez quand vous devez verifier la PROTECTION FOUDRE (NF EN 62305) : analyse du risque annuel (Ng x surface equivalente 9πH2 x environnement x usage), paratonnerre (PDA ou cage maillee) requis si risque > 1e-4/an (seuil simplifie), parafo
  • cao_bim_soutenement · Appelez quand vous devez verifier un MUR DE SOUTENEMENT (Rankine, EC7) : poussee active des terres (Ka = tan2(45-phi/2), avec surcharge), securite au GLISSEMENT (mu x poids / poussee >= 1,5) et au RENVERSEMENT (moment stabilisant / renversa
  • cao_bim_diagnostics · Appelez quand vous devez verifier les DIAGNOSTICS OBLIGATOIRES AVANT TRAVAUX : DTA amiante (batiment d'avant 1997, valable 6 ans, diagnostiqueur certifie), CREP plomb (avant 1949, a actualiser si plomb detecte depuis plus d'un an), etat par
  • cao_bim_intrusion · Appelez quand vous devez verifier la SECURITE INTRUSION (EN 1627 / NF A2P) : classification des acces (porte d'entree et fenetres accessibles >= RC2), alarme certifiee NF A2P pour les locaux sensibles (commerce, bureau, ERP), eclairage exte
  • cao_bim_sprinkler · Appelez quand vous devez verifier un SPRINKLAGE (regles APSAD, indicatif) : necessite (entrepot/commerce/industrie > 3 000 m2 ou ERP 1re-2e categorie), reserve d'eau >= densite de la classe de risque (OH1 4 / OH2 5 / OH3 7,5 / OH4 10 L/min/
  • cao_bim_signaletique · Appelez quand vous devez verifier la SIGNALETIQUE PMR (arrete 20/04/2017) : pictogrammes d'accessibilite (sourds/malentendants) aux accueils sonorises, bandes podotactiles d'eveil de vigilance en haut d'escalier, contrastes visuels (portes,
  • cao_bim_vibrations · Appelez quand vous devez verifier le CONFORT VIBRATOIRE d'un plancher (EC5) : frequence propre estimee f1 ~ 18/racine(delta) (delta = fleche sous charge permanente), exigence >= 8 Hz en residentiel, fleche <= 14 mm, usage declare. scene : p
  • cao_bim_legionelles · Appelez quand vous devez verifier la PREVENTION LEGIONELLES d'un reseau ECS collectif (arretes 30/11/2005 et 1/02/2010) : temperature de stockage >= 55 C, bouclage avec retour >= 50 C, purge de fond de ballon periodique (carnet sanitaire) e
  • cao_bim_eclairage_exterieur · Appelez quand vous devez verifier l'ECLAIRAGE EXTERIEUR (EN 12464-2, arrete 27/12/2018) : niveaux par zone (parking 20 lux, cheminement 10, acces 30), uniformite parking >= 0,25, densite de puissance <= 2 W/m2, extinction nocturne (23h-6h)
  • cao_bim_aev · Appelez quand vous devez verifier le CLASSEMENT AEV des menuiseries (NF DTU 36.5) : classement A*E*V* (air/eau/vent) >= exigence de l'exposition (faible A2E3V2, moderee A3E5V2, forte A4E6V3), exposition declaree, pose avec joints d'etanchei
  • cao_bim_emergence_sonore · Appelez quand vous devez verifier l'EMERGENCE SONORE des equipements exterieurs (PAC, clim, VMC — code de la sante R. 1334-31) : niveau a la limite de propriete Lp = Lw - 20.log(d) - 11 (ecran -5 dB), emergence face au bruit residuel declar
  • cao_bim_parking · Appelez quand vous devez verifier un PARKING : dimensions des places (standard >= 2,30 x 5,00 m, PMR >= 3,30 x 5,00), largeur des allees (double sens >= 5,50 m, sens unique >= 3,50), ventilation mecanique et detection CO des parkings couver
  • cao_bim_suivi_energetique · Appelez quand vous devez verifier le SUIVI ENERGETIQUE d'un batiment (exploitation) : plan de comptage par usage (chauffage, ECS, eclairage, prises, auxiliaires), DERIVE entre consommation mesuree et cible Cep (alerte > +10 %), protocole IP
  • cao_bim_cuisine_pro · Appelez quand vous devez verifier une CUISINE PROFESSIONNELLE : extraction de la hotte >= 30 m3/h par kW installe, compensation d'air entre 80 et 90 % de l'extraction (legere depression), filtres a graisse declares et entretenus, extinction
  • cao_bim_bruit_chantier · Appelez quand vous devez verifier le BRUIT DE CHANTIER au voisinage : niveau au riverain depuis les engins declares (Lw, distance, ecran -5 dB), limites indicatives 70 dB(A) jour / 60 nuit, emergence face au bruit residuel (5 dB(A) jour / 3
  • cao_bim_niveaux · Appelez quand vous devez organiser la maquette par NIVEAUX (etages, a la Revit) : creer des niveaux nommes avec leur altitude (action=creer, nom, z_mm), les lister (action=niveaux), PLACER une instance sur un niveau (action=placer : le z es
  • cao_bim_reservations · Appelez quand vous devez verifier les RESERVATIONS ENTRE LOTS (coordination EXE) : statut de chaque reservation (tremie, fourreau, reservation) avant coulage (alerte a J-7), chevauchements entre reservations sur le meme element, tracabilite
  • cao_bim_eau_froide · Appelez quand vous devez verifier le RESEAU D'EAU FROIDE SANITAIRE : temperature de distribution <= 25 C (arrete qualite de l'eau), gaines mitoyennes de reseaux chauds isolees, protection hors gel des reseaux exposes et materiaux conformes
  • cao_bim_registre_securite · Appelez quand vous devez verifier le REGISTRE DE SECURITE (exploitation) : les equipements presents dans la scene (extincteurs, BAES, ascenseurs, sprinkler, gaz, paratonnerre, alarme intrusion) sont detectes, chacun exige sa fiche de verifi
  • cao_bim_desenfumage · Appelez quand vous devez verifier le DESENFUMAGE (ERP CO 43, IT 246) : systeme requis pour les locaux > 300 m2 (cat. 1-4) ou > 100 m2 (5e cat.), surface utile d'exutoires >= 1/200 de la surface du local (naturel), amenee d'air >= exutoires
  • cao_bim_renovation · Appelez quand vous devez construire le PAQUET DE RENOVATION ENERGETIQUE : Cep apres travaux (gains par poste : combles, murs, menuiseries, ventilation, chauffage), cible BBC renovation (<= 100 kWh/m2), economie annuelle et retour sur invest
  • cao_bim_reverberation · Appelez quand vous devez verifier la CORRECTION ACOUSTIQUE d'une salle : temps de reverberation TR60 par la formule de Sabine (TR = 0,16 V / somme S*alpha), cible par usage (bureau 0,6 s, reunion 0,8 s, circulation 1,2 s), aire d'absorption
  • cao_bim_structure_scene · Appelez quand vous devez PREDIMENSIONNER TOUTE LA STRUCTURE d'une scene CAO d'un coup : dalles (epaisseur >= portee / 30), poteaux (elancement lambda = Lf/i <= 70), poutres (h >= L/15 et b >= 0,3 h), voiles de contreventement dans les DEUX
  • cao_bim_pieces_equipees · Appelez quand vous devez EQUIPER LES PIECES SELON LEUR USAGE depuis le catalogue fabricants : composition du kit minimum par piece (cuisine : evier, extraction, eclairage ; salle de bain : WC suspendu Geberit, vasque, receveur, seche-servie
  • cao_bim_calepinage · Appelez quand vous devez CALEPINER LES REVETEMENTS (plan de pose EXE) : rangées entieres et carreaux coupes par piece, nombre de carreaux a acheter, dechet (%) face aux regles de l'art — dechet <= 10 %, aucune coupe < 1/3 du carreau (CAL-CO
  • cao_bim_coupes · Appelez quand vous devez COUPER LA MAQUETTE (auteur) : coupe verticale a x fixe ou y fixe listant les elements traverses (murs, poteaux, dalles) avec leurs altitudes, hauteurs libres de plancher a plancher, puis verification — niveaux stric
  • cao_bim_referencement_fabricants · Appelez quand vous devez REFERENCER LES MENUISERIES sur le catalogue fabricants (EXE) : attribue a chaque ouverture le type fabricant le plus proche (fenetre PVC/alu/bois par gabarit, porte interieure 63/73/83/93, porte d'entree, baie couli
  • cao_bim_planchers · Appelez quand vous devez PREDIMENSIONNER LES PLANCHERS (structure) : systeme declare (hourdis, dalle_pleine, bois), portee admissible (7 m hourdis, 8 m dalle, 5 m bois), epaisseur minimale (160 mm hourdis, L/30 dalle pleine, 200 mm bois), e
  • cao_bim_reperage_lots · Appelez quand vous devez REPERER LES ELEMENTS PAR LOT pour les plans d'execution (EXE) : codifie chaque element de la maquette par lot (GO-MUR-01, ME-OUV-03, PL-RES-02), puis verifie — chaque conteneur appartient a un lot connu (RP-LOT), co
  • cao_bim_neige · Appelez quand vous devez CALCULER LA CHARGE DE NEIGE sur une toiture (EC1-1-3) : zone francaise (1A a 5, sk au sol), pente de toiture (coefficient de forme mu : 0,8 <= 30 deg, lineaire 30-60, 0 >= 60), charge s = mu x sk x ce x ct, verifica
  • cao_bim_pose_niveaux · Appelez quand vous devez REPARTIR LES EQUIPEMENTS FABRICANTS PAR NIVEAU (auteur) : chaque piece est rattachee a son niveau, son kit fabricant est resolu (cuisine, salle de bain, chambre...), et le plan de pose par niveau est consolide (equi

The first 100 are shown.

What "online" means: the server answered an MCP connection at the time of the check. It is not a guarantee of security, quality or continuous uptime. How we test: we open an MCP session and ask for the tool list, as an AI assistant would. We never run a tool and never send a key. Checked every few days. Method

Is this your server? Monitoring Pro: a check every 30 minutes and an email within the hour when it stops answering. Launch offer: $39.99 once, for life.

Facts & evidence

Each fact shows where it was seen and when.
FactValueEvidenceSourceLast confirmed
Version1.2.1DECLAREDSRC-001 Official MCP Registry20h ago
Hosted endpointhttps://synergieloc.fr/mcp, https://synergieloc.fr/mcp/v2DECLAREDSRC-001 Official MCP Registry20h ago
Local install (package)noDECLAREDSRC-001 Official MCP Registry20h ago
Remote access (hosted)yesDECLAREDSRC-001 Official MCP Registry20h ago
Websitehttps://synergieloc.fr/api-iaDECLAREDSRC-001 Official MCP Registry20h ago
Registry statusactiveDECLAREDSRC-001 Official MCP Registry20h ago
MCP serveryesDECLAREDSRC-001 Official MCP Registry20h ago

Change history

  • VERSION16 Nov 2026
    1.2.0 → 1.2.1
  • VERSION13 Nov 2026
    1.1.0 → 1.2.0

Is this page accurate?

Flag it and our robot re-checks the official source. Reports never change a score.

Do you run Synergieloc — French real estate & building CAD/BIM? Know when it stops answering

For publishers · optional

Its hosted endpoint can be monitored. Monitoring Pro connects every 30 minutes like an AI assistant, emails you within the hour when it stops answering, keeps a 90-day availability history and adds your answer rate to your badge.

Monitor Synergieloc — French real estate & building CAD/BIMLaunch offer $39.99 once, for life instead of $9.99/month · All plans

Monitoring never changes a score or a rank.

Are you the publisher of Synergieloc — French real estate & building CAD/BIM?

Free · show your listing

An independent listing builds trust with your buyers. Announce it, and add the badge to your website or README.

Announce it on LinkedIn
Listed on Electra IndexListed on Electra Index
<a href="https://electraindex.com/mcp/immobilier?utm_source=badge&utm_medium=share&utm_campaign=listing"><img src="https://electraindex.com/api/badge/immobilier/card" width="260" height="72" alt="Listed on Electra Index"></a>

Questions about Synergieloc — French real estate & building CAD/BIM

How do I connect Synergieloc — French real estate & building CAD/BIM?

Use the hosted endpoint https://synergieloc.fr/mcp in your assistant's MCP settings. The exact settings are in "How to connect" above, as declared in the Official MCP Registry.

What tools does Synergieloc — French real estate & building CAD/BIM offer?

When Electra Index connected on 17 Nov 2026, it listed 560 tools: cao_bim_conformite, cao_bim_aller_retour, cao_bim_disciplines, cao_bim_modele, cao_bim_familles, cao_bim_doe, cao_bim_federation, cao_bim_fabricants and more. The full list is in "Live check" above.

Is Synergieloc — French real estate & building CAD/BIM online?

Yes. Its hosted endpoint answered an MCP connection from Electra Index 5h ago.