Reviews
No review yet. Used calc.engineer? Be the first to help others choose.What it does
calc.engineer is an MCP server, a connector that lets an AI assistant use it as a tool. It is hosted: an assistant connects to it over the internet, nothing to install.
No capability identified yet from its description.
Facts come from the Official MCP Registry, as declared by the publisher. Capabilities are matched automatically (low confidence). None of this is a test of the tool.
At a glance
How to connect
As declared in the Official MCP Registry · hosted endpoint tested by Electra Index 2d ago (live check)Hosted endpoint
https://calc.engineer/mcpstreamable-http
In Claude Code: claude mcp add --transport http calc-engineer https://calc.engineer/mcp
MCP settings (Claude Desktop, Cursor and other MCP clients)
{
"mcpServers": {
"calc-engineer": {
"url": "https://calc.engineer/mcp"
}
}
}Live check
Electra Index connected to the hosted endpoint 2d agoONLINE calc.engineer answered an MCP connection on 14 Nov 2026 and introduced itself as calc-engineer 1.0.0 (MCP protocol 2025-06-18).
89 tools offered to AI assistants
fspl· Calculate free-space path loss (FSPL) in decibels using the ITU-R P.525 standard formula. Given a frequency in MHz and distance in kilometres, returns the expected signal attenuation in an ideal line-of-sight radio link with no obstacles, rlink_budget· Compute a full RF link budget from transmitter power, frequency, distance, and antenna gains. Calculates EIRP, free-space path loss (ITU-R P.525), received power at the receiver, and link margin relative to an optional receiver sensitivitydipole· Calculate physical dimensions of a dipole antenna for a given frequency. Returns half-wave or quarter-wave element length in metres, feet, and inches. A half-wave dipole is the most common resonant antenna with approximately 2.15 dBi gain.microstrip· Calculate PCB microstrip trace width for a target characteristic impedance using the Hammerstad-Jensen closed-form equations. Given target impedance (Z0), substrate dielectric constant (er), substrate height, and copper weight, returns thedbm_convert· Convert a power level in dBm to milliwatts, watts, dBW, and RMS voltage across a given impedance. dBm is the standard unit for RF power referenced to 1 milliwatt. This tool is essential when interfacing datasheets (which use dBm) with circunoise_figure_cascade· Calculate the cascaded noise figure of a multi-stage receiver chain using the Friis formula. Each stage has a noise figure and gain in dB. The first stage dominates overall system noise, which is why low-noise amplifiers (LNAs) are placed avswr· Convert between VSWR, return loss, and reflection coefficient — provide any one parameter and get all related impedance-mismatch metrics. Computes VSWR (voltage standing wave ratio), return loss in dB, reflection coefficient (gamma), mismatattenuator_pi· Design a Pi-topology resistive attenuator pad. Given a desired attenuation in dB and characteristic impedance (default 50 ohm), computes the three resistor values for a symmetrical Pi-pad network. The Pi attenuator uses two shunt resistorsattenuator_tee· Design a Tee-topology resistive attenuator pad. Given a desired attenuation in dB and characteristic impedance (default 50 ohm), computes the three resistor values for a symmetrical T-pad network. The Tee attenuator uses two series resistorfresnel_zone· Calculate the Fresnel zone radius at the midpoint of a radio link. Given frequency in MHz, link distance in kilometres, and zone number (1-5), returns the Fresnel zone radius in metres and feet, plus the 60% clearance threshold used in pracwavelength_freq· Convert between radio frequency and wavelength. Provide either frequency in MHz or wavelength in metres, and get the full set of equivalent values: frequency in MHz and GHz, wavelength in metres, centimetres, millimetres, and feet. Essentiaspice_template· Generate a complete SPICE netlist from a parameterized template. Supports common circuit topologies: low-pass RC filter, voltage divider, common emitter amplifier. Returns a ready-to-simulate netlist string that can be passed directly to sp
Show 77 more
spice_simulate· Run a SPICE circuit simulation directly in the worker. Accepts a standard SPICE netlist and performs operating-point (.op), DC sweep (.dc), AC frequency sweep (.ac), or transient (.tran) analysis using a built-in modified-nodal-analysis englora_airtime· Calculates LoRa packet time-on-air using the Semtech AN1200.13 formula. Computes symbol duration, preamble time, payload symbol count, effective data rate, and the minimum transmission interval for 1% duty cycle compliance. Essential for casnr_margin· Computes LoRa link SNR margin by comparing received power against the noise floor and the spreading-factor-dependent demodulation threshold from the Semtech SX1276 datasheet. Calculates receiver noise floor from thermal noise (-174 dBm/Hz),channel_utilization· Estimates Meshtastic or LoRa mesh channel utilization percentage based on node count, message rate, and per-packet airtime. Determines how much of the shared radio channel is occupied and computes the maximum number of nodes before exceedinlora_range_estimate· Estimates LoRa maximum communication range by computing the free-space path loss (FSPL) link budget and applying terrain-dependent correction factors. Calculates total link budget from transmit power, antenna gains, and receiver sensitivitylora_sensitivity· Calculates LoRa receiver sensitivity from spreading factor, bandwidth, and noise figure using the Semtech SX1276 datasheet SNR thresholds. Computes the noise floor from thermal noise density (-174 dBm/Hz), channel bandwidth, and receiver noduty_cycle_budget· Calculates LoRa duty cycle budget for EU868, US915, AS923, and AU915 regulatory regions. Computes maximum messages per hour, minimum transmission interval, and effective data rate under regional duty cycle constraints. EU868 and AS923 enformeshtastic_range· Estimates Meshtastic node communication range using real hardware profiles and firmware channel presets. Combines device-specific TX power and antenna gain (Heltec V3, RAK WisBlock, T-Beam, T-Beam Supreme, Station G2) with firmware modem preirp_compliance· Checks EIRP (Effective Isotropic Radiated Power) compliance against regional regulatory limits for LoRa and Meshtastic operation. Computes EIRP from transmit power, antenna gain, and cable loss, then compares against FCC (US, 36 dBm), ETSImeshtastic_power· Calculates Meshtastic node power consumption and battery runtime using device-specific power profiles and firmware role-based duty cycling. Models sleep, RX, and TX current draw for Heltec V3, RAK WisBlock, T-Beam, T-Beam Supreme, and Statilora_param_optimizer· Recommends optimal LoRa spreading factor, bandwidth, and TX power based on target range, terrain, and optimization priority. Iterates through all SF (7-12) and BW (125/250/500 kHz) combinations, computing achievable range, airtime, data ratzfs_capacity· Calculate usable ZFS pool capacity for any RAID level including stripe, mirror, raidz1, raidz2, and raidz3. Computes raw capacity, parity overhead, data disk count, usable terabytes after ZFS metadata overhead (checksums, block pointers, ubzfs_ram· Calculate recommended RAM and ARC sizing for a ZFS storage pool based on workload type, pool size, deduplication status, and L2ARC cache size. Computes minimum and recommended RAM in gigabytes, ARC target size, and dedup table overhead. Acctcp_throughput· Calculate maximum TCP throughput using the Bandwidth-Delay Product (BDP) formula. Given link bandwidth and round-trip latency, computes the BDP (maximum in-flight data), achievable throughput with a given TCP window size, link utilization pwireguard_mtu· Calculate the optimal MTU for a WireGuard VPN tunnel interface with a detailed overhead breakdown. Accounts for WireGuard header (32 bytes), outer IP header (20 bytes IPv4 or 40 bytes IPv6), UDP header (8 bytes), and optional PPPoE encapsulsubnet_calculator· Calculate IPv4 subnet details from CIDR notation. Parses a CIDR block (e.g. 192.168.1.0/24) and returns the network address, broadcast address, subnet mask, wildcard mask, first and last usable host addresses, total and usable host counts,raid_iops· Estimate RAID array IOPS performance and latency for ZFS and traditional RAID configurations. Calculates maximum read IOPS, write IOPS (accounting for write penalty/amplification per RAID level), blended IOPS for a configurable read/write wpower_cost· Calculate total power consumption, electricity cost, and circuit requirements for a homelab. Enter each device's wattage to get daily/monthly/yearly kWh and cost at your local electricity rate. Accounts for cooling overhead via PUE (Power Ucooling_btu· Estimate the cooling load (BTU/hr) for a homelab or server closet based on equipment wattage, room dimensions, insulation quality, and solar exposure. All electrical power converts to heat — this tool calculates equipment heat output, envelrack_capacity· Quick rack space and weight sizing calculator for homelab and small data center racks. Enter your devices with their height in rack units, weight, and wattage to get total utilization, remaining free space, weight totals in lbs and kg, andnetwork_bandwidth· Plan and validate network link capacity for homelab workloads. Determine whether a 1G, 2.5G, 10G, or faster link can handle your concurrent streams (VMs, backups, media, iSCSI). Calculates effective bandwidth after TCP/IP overhead, total rethermal_enclosure· Estimate steady-state thermal behaviour of a rectangular enclosure (server rack, electronics housing, equipment cabinet) using a lumped-parameter energy balance with natural-convection and radiation correlations, or forced-flow air energy bheatsink_cfd· Analyze a forced-convection fin-array heatsink using established channel-flow correlations (developing laminar Nusselt, fin efficiency tanh(mH)/mH, parallel-plate friction). Computes base-to-air thermal resistance, pressure drop, base and fpcb_thermal· Estimate PCB component temperatures by solving a thermal resistance network (thermal↔electrical analogy) with the built-in MNA solver. Each component gets a junction node (package θjb from a typical-datasheet table), a local board node coupbattery_life· Calculates battery runtime and energy capacity given cell capacity in mAh, nominal voltage, and average current draw. Accounts for real-world discharge efficiency (Peukert-adjacent derating) to produce effective capacity, total energy in Whwire_gauge· Determines the minimum AWG (American Wire Gauge) conductor size for a given current, voltage, one-way cable distance, and maximum allowable voltage drop percentage. Supports copper and aluminum conductors. Computes round-trip resistance, acsolar_sizing· Sizes an off-grid solar power system by calculating the number of panels and battery bank capacity required for a given daily energy consumption. Accounts for system losses (inverter, wiring, charge controller), battery depth-of-discharge,ups_runtime· Estimates UPS (Uninterruptible Power Supply) backup runtime from battery specifications and connected load. Takes VA rating, watt rating, load in watts, and battery configuration (count, voltage, amp-hours) to compute effective stored energmah_to_wh· Converts battery capacity from milliamp-hours (mAh) to watt-hours (Wh), kilowatt-hours (kWh), and joules (J) given the nominal cell voltage. This is the most common battery unit conversion needed when comparing cells rated in mAh (e.g. 1865watts_to_amps· Converts electrical power in watts to current in amps (and milliamps) for a given voltage, using the DC power formula P = V * I. Also computes the implied load resistance via Ohm's law (R = V / I) assuming a purely resistive load. This is tvoltage_drop· Calculates voltage drop across a conductor run given current, wire length, AWG gauge, system voltage, and conductor material (copper or aluminum). Computes round-trip resistance, voltage drop in volts and percent, voltage at the load end, pbattery_charge_time· Estimates battery charge time given capacity in mAh, charge current in mA, charger efficiency, and initial state of charge. Accounts for real-world charging losses (typically 80-90% efficient) to produce time in hours and minutes, energy resolar_load_audit· Calculates total daily energy consumption from an appliance list — the critical first step before sizing solar panels or batteries. Enter each appliance with its wattage, hours of daily use, and quantity. Outputs total daily kWh (with confisolar_roi· Calculates solar system return on investment, payback period, and levelized cost of energy (LCOE). Models year-by-year savings accounting for panel degradation, utility rate inflation, federal Investment Tax Credit (ITC), state rebates, andbattery_autonomy· Calculates how many days a battery bank can sustain loads without solar input — critical for off-grid and backup power sizing. Accounts for depth of discharge, round-trip efficiency (lithium vs lead-acid), minimum state of charge, and optiostring_sizing· Calculates optimal solar panel string and MPPT configuration based on panel electrical specs, inverter/charge-controller MPPT limits, and site temperature extremes. Applies temperature coefficients to determine Voc at minimum temperature (cgenerator_offset· Compares total cost of ownership between a fuel generator and a solar+battery system over a configurable time horizon. Calculates yearly and cumulative costs for generator-only, solar-only (amortized), and hybrid scenarios. Accounts for fuewire_ampacity· Determine minimum wire gauge using NEC Table 310.16 ampacity ratings with full derating. Looks up base ampacity for copper or aluminum conductors at 60°C, 75°C, or 90°C insulation rating, then applies NEC 310.15(C)(1) ambient temperature coinverter_sizing· Size a DC-to-AC inverter for off-grid solar, battery backup, or mobile power systems. Computes the required continuous VA rating from total load watts and power factor, estimates surge capacity for motor-starting loads (3-7x rated power), apcb_layout· Turn a SPICE netlist into a fab-ready 2-layer PCB: assigns real footprints (0805, TO-92, DO-35, DIP-8, headers, LED, radial-cap), auto-places components (connectivity-aware; or use your own placement), routes a 2-layer maze router with viasvoltage_divider· Calculates output voltage, current draw, and power dissipation for a resistive voltage divider. Given an input voltage Vin and two resistor values R1 (upper) and R2 (lower), computes Vout = Vin * R2 / (R1 + R2), divider current, individualrc_filter· Computes the cutoff frequency, time constant, impedance, and phase shift of a first-order RC filter. Supports both lowpass and highpass topologies. The cutoff frequency is f = 1/(2*pi*R*C) where the signal is attenuated by 3 dB. The time colc_resonance· Calculates the resonant frequency of an LC circuit, along with optional Q factor and bandwidth when series resistance is provided. The resonant frequency f0 = 1/(2*pi*sqrt(L*C)) is where inductive and capacitive reactances cancel. Used forimpedance_match· Designs an L-network impedance matching circuit between two real impedances at a given frequency. Computes the required shunt and series reactive components (inductor and capacitor) to transform the source impedance to the load impedance. Ttrace_width· Calculates the minimum PCB trace width for a given current using the IPC-2221 standard formula. The IPC-2221 empirical equation relates current capacity to cross-sectional area and temperature rise: I = k * dT^0.44 * A^0.725, where k=0.048ohms_law· Solves Ohm's Law and the power equation given any two of four electrical quantities: voltage (V), current (I), resistance (R), and power (P). Uses V=IR, P=VI, P=I^2R, and P=V^2/R to derive the missing two values. Fundamental for every circuresistor_color_code· Decodes 4-band or 5-band resistor color codes into resistance value, tolerance, and min/max range. Accepts an ordered array of color names (left-to-right as printed on the resistor body). Supports standard EIA color codes including gold andled_resistor· Calculates the current-limiting resistor for driving one or more LEDs in series from a DC supply. Computes the exact resistance from R = (Vsupply - n*Vf) / I, then selects the nearest E24 standard resistor value. Reports the actual currenttimer_555· Calculates timing parameters for the ubiquitous NE555 / LM555 timer IC in astable (free-running oscillator) and monostable (one-shot pulse) modes. In astable mode, computes frequency, period, duty cycle, and HIGH/LOW durations from R1, R2,op_amp_gain· Calculate voltage gain and output for operational amplifier circuits in inverting, non-inverting, and differential configurations. For inverting: Av = -Rf/Ri with input impedance equal to Ri. For non-inverting: Av = 1 + Rf/Rg with very highcapacitor_charge· Calculates RC capacitor charge timing, energy storage, and transient voltages. Given resistance, capacitance, supply voltage, and optional initial voltage, computes the RC time constant (τ = R×C), time to reach standard charge thresholds (6pcb_via_current· Calculate PCB via current-carrying capacity using the IPC-2221 standard. A plated via is a hollow copper cylinder whose cross-sectional area is the annular ring of plating: A = pi * (D - t) * t, where D is the drill diameter and t is platinpower_supply_decoupling· Select bypass and bulk decoupling capacitors for IC power supply pins. Computes the target PDN (Power Distribution Network) impedance from supply current, voltage, and allowable ripple using Z_target = V_ripple / I_total. Recommends a ceramlog_calc· Compute logarithms of a positive number in any base. Returns the custom-base logarithm, natural logarithm (ln), common logarithm (log10), and binary logarithm (log2). Useful for signal processing (decibel calculations), information theory (sig_figs· Count significant figures in a number and optionally round to N significant figures. Accepts the number as a string to preserve trailing zeros (e.g. '1.200' has 4 sig figs). Applies standard sig fig rules: leading zeros do not count, trailiscientific_notation· Convert any number to scientific notation and engineering notation. Returns the coefficient, exponent, a formatted string with Unicode superscripts (e.g. '3.14 × 10²'), and engineering notation where the exponent is a multiple of 3. Usefulpercentage_calc· Calculate what percentage one number is of another. Given a value and a total, returns the percentage, decimal form, and simplified fraction. For example, 3 out of 4 yields 75%, 0.75, and '3/4'. Commonly used for test scores, survey resultspercentage_increase· Calculate the percentage change between an old value and a new value. Determines whether the change is an increase or decrease, the absolute change, and the percentage change. Essential for financial analysis (stock price changes, revenue gexponent_calc· Compute the result of raising a base to an exponent (base^exponent). Handles positive and negative exponents, fractional exponents, and zero. Returns the numeric result and a scientific notation string for very large or very small results.square_root· Compute the square root of a non-negative number. Returns the decimal result, whether the input is a perfect square, and a simplified radical form (e.g. '√12' simplifies to '2√3'). For integer inputs, factors are extracted from under the racircumference· Calculate the circumference and area of a circle given either a radius or diameter. Provide one or both; if both are given, radius takes precedence. Returns circumference (C = 2πr), area (A = πr²), and both radius and diameter for completenslope_calc· Calculate the slope, y-intercept, line equation, angle, and distance between two points in a 2D Cartesian plane. Given coordinates (x1, y1) and (x2, y2), computes slope (rise/run), y-intercept, the equation in slope-intercept form (y = mx +pythagorean_theorem· Solve for any side of a right triangle using the Pythagorean theorem (a² + b² = c²). Provide any two of the three sides (a, b, c) and the missing side is computed. Also returns the triangle area (0.5 * a * b), perimeter, and confirms it isp_value· Calculate the p-value for a z-score or t-statistic. Supports one-tailed (left or right) and two-tailed hypothesis tests using either the standard normal distribution or the Student's t-distribution when degrees of freedom are specified. Retconfidence_interval· Calculate the confidence interval for a sample mean. Given a sample mean, sample size, standard deviation, and confidence level, computes the margin of error, lower and upper bounds, critical z-score, and standard error. Supports finite popsales_tax· Calculates total cost including sales tax for a purchase. Given a unit price, tax rate percentage, and optional quantity, computes the subtotal (price times quantity), the tax amount rounded to two decimal places, and the final total. Usefusalary_to_hourly· Converts compensation between annual salary, monthly pay, weekly pay, and hourly wage. Accepts any of the four pay periods as input and derives all others. Uses configurable hours per week (default 40) and weeks per year (default 52). Dailyloan_amortization· Computes a full loan amortization schedule given principal, annual interest rate, and term in months. Returns the fixed monthly payment, total interest, total payments, and a month-by-month breakdown of principal vs interest. Supports optiocompound_interest· Calculates compound interest growth over time using the formula A = P(1 + r/n)^(nt). Given a principal, annual rate, duration in years, and compounding frequency, returns the future value, total interest earned, effective annual rate (APY),test_grade· Calculates a test or exam grade from the number of correct answers and total questions. Returns the percentage score, letter grade, points missed, and GPA points. Supports US grading (A/B/C/D/F with 4.0 GPA scale), UK grading (First/2:1/2:2square_footage· Calculates area and perimeter for common shapes — rectangle, circle, or triangle — in both imperial and metric units. Returns area in square feet, square meters, and acres, plus perimeter in feet and meters. For rectangles: area = length *unit_convert· Convert between units across 10 categories: length (m, km, mi, ft, in, yd, nmi), mass (kg, lb, oz, g, ton), volume (l, gal, ml, cup, fl_oz), area (m2, ft2, acre, hectare), speed (mps, kph, mph, knot), pressure (pa, psi, bar, atm, mmhg), enehex_converter· Convert numbers between hexadecimal, binary, decimal, and octal bases. Accepts any base as input (prefix 0x for hex, 0b for binary, 0o for octal, or plain decimal) and returns all four representations simultaneously. Also reports bit width,timestamp_converter· Convert between Unix timestamps and human-readable date/time formats. Accepts Unix epoch (in seconds or milliseconds), ISO 8601 strings, or 'now' for the current time. Returns both Unix seconds and milliseconds, ISO 8601 UTC string, date anbmi_calculator· Calculate Body Mass Index (BMI) from weight and height using the WHO standard formula. Supports metric (kg/cm) and imperial (lbs/inches) units. Returns the BMI value, WHO classification (Underweight, Normal, Overweight, Obese Class I-III),tip_calculator· Calculate tip and split a restaurant bill among multiple people. Given a bill amount, tip percentage, and number of diners, returns the tip amount, total with tip, per-person share, and effective tip percentage. Supports rounding up to thedate_difference· Calculate the difference between two dates in days, weeks, months, years, and business days. Accepts dates in YYYY-MM-DD format. Returns the absolute difference (order doesn't matter) plus a flag indicating whether the end date is in the fu
What "online" means: the server answered an MCP connection at the time of the check. It is not a guarantee of security, quality or continuous uptime. How we test: we open an MCP session and ask for the tool list, as an AI assistant would. We never run a tool and never send a key. Checked every few days. Method
Is this your server? Monitoring Pro: a check every 30 minutes and an email within the hour when it stops answering. Launch offer: $39.99 once, for life.
Facts & evidence
Each fact shows where it was seen and when.| Fact | Value | Evidence | Source | Last confirmed |
|---|---|---|---|---|
| Hosted endpoint | https://calc.engineer/mcp | DECLARED | SRC-001 Official MCP Registry | 1d ago |
| Local install (package) | no | DECLARED | SRC-001 Official MCP Registry | 1d ago |
| Remote access (hosted) | yes | DECLARED | SRC-001 Official MCP Registry | 1d ago |
| Website | https://calc.engineer | DECLARED | SRC-001 Official MCP Registry | 1d ago |
| Registry status | active | DECLARED | SRC-001 Official MCP Registry | 1d ago |
| Version | 1.0.0 | DECLARED | SRC-001 Official MCP Registry | 1d ago |
| MCP server | yes | DECLARED | SRC-001 Official MCP Registry | 1d ago |
Change history
Is this page accurate?
Flag it and our robot re-checks the official source. Reports never change a score.Is calc.engineer still online?
Free alerts · no account▲ 0Do you run calc.engineer? Know when it stops answering
For publishers · optionalIts hosted endpoint can be monitored. Monitoring Pro connects every 30 minutes like an AI assistant, emails you within the hour when it stops answering, keeps a 90-day availability history and adds your answer rate to your badge.
Monitoring never changes a score or a rank.
Questions about calc.engineer
How do I connect calc.engineer?
Use the hosted endpoint https://calc.engineer/mcp in your assistant's MCP settings. The exact settings are in "How to connect" above, as declared in the Official MCP Registry.
What tools does calc.engineer offer?
When Electra Index connected on 14 Nov 2026, it listed 89 tools: fspl, link_budget, dipole, microstrip, dbm_convert, noise_figure_cascade, vswr, attenuator_pi and more. The full list is in "Live check" above.
Is calc.engineer online?
Yes. Its hosted endpoint answered an MCP connection from Electra Index 2d ago.